首页> 外文会议>International symposium on high voltage engineering >Simplified Approach for Investigating Overvoltages in DC Cables in a ±320 kV Symmetrical Monopolar HVDC System
【24h】

Simplified Approach for Investigating Overvoltages in DC Cables in a ±320 kV Symmetrical Monopolar HVDC System

机译:研究±320 kV对称单极高压直流输电系统中直流电缆中过电压的简化方法

获取原文

摘要

Transient analysis of DC cable systems has gained momentum, especially due to pressing demands on the availability and reliability of offshore interconnectors. Such investigations form a vital part of the overall insulation coordination studies, which are typically performed by utilities and transmission system operators. Detailed converter models are typically limited to the respective manufacturers, and from a cable manufactory perspective, the converters are usually considered as a black box component. This makes it challenging for cable manufacturers to obtain such models for performing studies on their DC cables, mainly aimed at the converter/cable interface. In this paper, reduced converter models are utilized for performing DC-side fault studies. Detailed cable models have been implemented, considering the properties of every cable layer. The focus is on pole-to-ground faults for a symmetric monopolar half bridge VSC based modular multilevel system. The simulation results are analyzed and recreated in the form of a special overvoltage test performed on a full-scale DC cable system, i.e. a cable, along with joints and terminations. Based on the presented study results, reduced converter models can be utilized as an alternative to detailed models within the cable industry. In this manner, it is possible to achieve a first-hand impression of the profile of transient stresses that the DC cables may experience. This can provide an advantage regarding developmental activities, especially in designing special and non-standard high voltage tests.
机译:直流电缆系统的瞬态分析获得了发展动力,特别是由于对离岸互连器的可用性和可靠性提出了迫切的要求。此类调查构成了总体绝缘协调研究的重要组成部分,通常由公用事业和传输系统运营商执行。详细的转换器模型通常仅限于各自的制造商,并且从电缆制造的角度来看,转换器通常被视为黑匣子组件。这给电缆制造商带来挑战,即要获得此类模型以对其直流电缆进行研究,而这些模型主要针对转换器/电缆接口。在本文中,精简的转换器模型用于执行直流侧故障研究。考虑到每个电缆层的特性,已经实施了详细的电缆模型。重点是基于对称单极半桥VSC的模块化多级系统的极对地故障。对仿真结果进行分析并以特殊的过压测试的形式重新创建,该测试在全尺寸DC电缆系统(即电缆)以及接头和端子上进行。根据提出的研究结果,可以使用简化的转换器模型替代电缆行业中的详细模型。以这种方式,可以对直流电缆可能会遇到的瞬态应力的轮廓产生第一手的印象。这可以为开发活动提供优势,尤其是在设计特殊和非标准的高压测试中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号