Once power transformer has been installed in service, it is degraded by thermal, electrical and mechanical stresses. To upkeep its condition and prevent catastrophic consequences from its failure the preventive and condition-based maintenances should be applied appropriately. The appropriate maintenances are considered based on power transformer usage risk, which is evaluated from present condition and importance of power transformer. To determine the present condition, the health index of power transformer and its components are at first determined by scoring the test results of visual inspection, electrical and insulating oil tests. Then, the obtained scores and weights, which were determined by applying the analytical hierarchy process to brainstorm the utility's expertise, were further calculated as component and overall health index of power transformer. Moreover, the major concerns of power transformer usage, such as loading percentage, load importance, redundancy, system fault level, number of through fault per year, transformer age, operation and maintenance satisfaction, are evaluated as importance index of power transformer by scoring and weighting technique. Then, the health and importance indices are coherently considered to access power transformer usage risk displayed on risk matrix. The aforementioned procedures were developed in Microsoft Excel to access 67 transformer's usage risks in Thailand's distribution grid. The software was developed to display the result as traffic light color as red, yellow and green for high, moderate and low usage risk respectively. The obtained risk are used to manage maintenance strategies and proper usage of power transformer according to its condition and usage risk.
机译:一旦电源变压器投入使用,它就会因热,电和机械应力而退化。为了维护其状况并防止其故障造成灾难性后果,应适当地进行预防性维护和基于状况的维护。根据电力变压器的使用风险来考虑适当的维护,该风险是根据电力变压器的现状和重要性来评估的。为了确定当前状态,首先通过对目视检查,电气和绝缘油测试的测试结果评分来确定电力变压器及其组件的健康指数。然后,将通过应用层次分析法集思广益的公用事业专业知识而确定的得分和权重进一步计算为电力变压器的组件和总体健康指数。此外,通过评分和评估,将电力变压器使用的主要考虑因素,如负荷百分比,负荷重要性,冗余度,系统故障水平,每年的直通故障数,变压器寿命,运行和维护满意度等,评估为电力变压器的重要性指标。加权技术。然后,将健康和重要性指标连贯考虑,以访问风险矩阵上显示的电力变压器使用风险。前面提到的过程是在Microsoft Excel中开发的,用于访问泰国配电网中67台变压器的使用风险。开发该软件的目的是将交通信号灯的颜色显示为红色,黄色和绿色,分别表示高,中和低使用风险。所获得的风险可用于根据其状况和使用风险来管理电源变压器的维护策略和正确使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号