【24h】

Load Testing of Two Separate Rotor Axial Flux Permanent Magnet Motor

机译:两个独立转子轴向磁通永磁电动机的负载测试

获取原文

摘要

One of the most important issues that must be considered after the design and construction of an electric motor is the loading test. By loading test, operational characteristic of a motor can be extracted. Recently, double-sided axial flux permanent magnet motors attracted many attentions. In this paper, the loading test of two separate rotor axial flux permanent magnet motor is studied using the finite element method. Results show that the aforementioned motor has better load flexibility but when the load difference in the two rotors becomes larger, power factor and efficiency of motor decreased.
机译:在电动机的设计和构造之后必须考虑的最重要的问题之一是负载测试。通过负载测试,可以提取电动机的运行特性。近来,双面轴向磁通永磁电动机引起了很多关注。本文采用有限元方法研究了两个分开的转子轴向磁通量永磁电动机的负载试验。结果表明,上述电动机具有较好的负荷柔性,但是当两个转子的负荷差变大时,电动机的功率因数和效率降低。