Comparative Examination of Iterative and Non- Iterative Algorithms for Partial Discharge Location Approximation in High Voltage Equipment

机译:高压设备局部放电位置近似的迭代算法与非迭代算法的比较研究

获取原文

摘要

For the stability and reliability of the electricity system, the diagnostic tests of high-voltage equipment are of utmost importance. Partial discharges often precede major failures, which can be prevented by detecting and locating these discharges in time. While standardized methods are used for the detection of partial discharges, there are no generally used techniques for the approximation of their spatial position, despite the potential economic benefits of using such methods. This paper focuses on the comparison of iterative and non-iterative location approximation algorithms that process the captured emitted electromagnetic pulses of the discharges. The aim of the research is to find the most suitable location approximation method for a measuring and signal processing system that could be applied during the factory acceptance tests of high voltage equipment.
机译:为了电力系统的稳定性和可靠性,高压设备的诊断测试至关重要。局部放电通常在重大故障之前发生,这可以通过及时检测和定位这些放电来避免。尽管使用标准方法来检测局部放电,但是尽管使用这种方法具有潜在的经济利益,但仍没有普遍使用的技术来估计其空间位置。本文着重比较处理捕获的放电放电电磁脉冲的迭代和非迭代位置逼近算法的比较。研究的目的是为测量和信号处理系统找到最合适的位置近似方法,该方法可在高压设备的工厂验收测试中使用。