In order to solve the problems of the existing islanding detection methods, the relationship between the structural features and fault characteristics of photovoltaic power generation system, and the difference between normal grid-connected operation and islanding operation are studied in this paper. According to the difference, a new principle about the anti-islanding protection is proposed, which is implemented by using impedance characteristic frequency sequence components and has no detecting blind area. The principle can quickly identify islanding state by detecting impedance component at the PCC point even in the case of single-phase and two-phase disconnection, and it can not affect the quality of power system. The simulation results show that this method can effectively detect the island and has no detection zones. And it's response is fast and has no impact on the power quality.
机译:为了解决现有岛屿检测方法的问题,研究了光伏发电系统的结构特征和故障特性的关系,以及本文研究了正常电网连接的运行和岛屿运行的差异。根据差异,提出了一种关于反岛保护保护的新原理,该原理是通过使用阻抗特征频率序列组分来实现的,并且没有检测盲区域。即使在单相和两相断开的情况下,也可以通过检测PCC点处的阻抗分量来快速识别孤岛状态,并且它不能影响电力系统的质量。仿真结果表明,该方法可以有效地检测岛屿并没有检测区域。它的反应是快速的,对电力质量没有影响。