首页> 外文会议>International Conference on Measurement >Application of fourier series to determine the measurements error of harmonics with selected power quality analyzers
【24h】

Application of fourier series to determine the measurements error of harmonics with selected power quality analyzers

机译:傅立叶系列应用傅立叶系列测量谐波与所选电能质量分析仪的测量误差

获取原文

摘要

The paper presents examples of the results of experimental research concerning the influence of input signal RMS on the measurement error of harmonics using selected power quality analyzers. The experiments were carried out in a designed and prepared measuring system. The system makes it possible to set selected testing signals. In the case considered, the input signals were, respectively, sinusoidal signal, triangle signal, rectangular signal and full-wave rectification signal. Based on the expansion of selected functions in the trigonometric Fourier series, the RMS values of consecutive harmonics were obtained, which became the reference values. Metrological interpretation of the obtained results, analysis of errors, and formulation of conclusions were presented in the paper.
机译:本文介绍了使用所选电能质量分析仪对谐波测量误差的影响的实验研究结果。实验在设计和制备的测量系统中进行。系统可以设置所选择的测试信号。在考虑的情况下,输入信号分别是正弦信号,三角形信号,矩形信号和全波整流信号。基于三角傅里叶系列中所选功能的扩展,获得了连续谐波的RMS值,成为参考值。本文提出了对所得结果,对误差分析和结论的分析和制剂的计量解释。