Sensorless Active Damping of LCL_Filter based on MRAS Estimator for Single-Phase Grid-Connected Inverter

机译:基于MRAS估计器的单相并网逆变器LCL_Filter的无传感器有源阻尼

获取原文

摘要

To meet standards regarding grid-tied systems, LCL filters are used instead of L filters because they allow lower inductances while reducing cost and size. However, LCL filters present resonance that cause instability issues. In view of this, two damping methods were proposed in the literature: Passive and Active Damping. Active damping techniques are preferred to avoid additional losses with passive techniques and thereby increasing the inverter efficiency but need the use of an additional sensor to measure the capacitor filter current.This paper addresses a MRAS (Model Reference Adaptive System) based capacitor filter estimator with an active damping current control of a single phase grid connected inverter.In order to guarantee the robustness of the designed MRAS estimator, the inverter control operation is tested under a wide range of grid impedance variation.
机译:为了满足有关并网系统的标准,使用LCL滤波器代替L滤波器,因为它们允许较低的电感,同时降低了成本和尺寸。但是,LCL滤波器会产生谐振,从而引起不稳定性问题。有鉴于此,文献中提出了两种阻尼方法:被动阻尼和主动阻尼。首选有源阻尼技术来避免无源技术带来的额外损耗,从而提高逆变器效率,但需要使用一个额外的传感器来测量电容器滤波电流。单相并网逆变器的有源阻尼电流控制。为了确保设计的MRAS估计器的鲁棒性,在大范围的电网阻抗变化范围内测试了逆变器控制操作。