首页> 外文会议>International conference on transportation engineering >Energy Absorption Level Test of Tunnel Lining Section Crossing Active Fault
【24h】

Energy Absorption Level Test of Tunnel Lining Section Crossing Active Fault

机译:隧道衬砌横穿活动断层的能量吸收水平试验

获取原文

摘要

In recent years, research showed that the tunnels may be seriously damaged when crossing fault zone. Therefore, the anti-shock designation of lining structure in fault zone is particularly prominent. Through the drop-weight test, this paper researched the damping level of the plain concrete lining, reinforced concrete lining, and rubber lining in circular direction. The test data show that the anti- seismic of reinforced concrete is better than plain concrete. The seismic load absorption ability of rubber lining is much greater than concrete lining. Through numerical simulation, we found the energy absorption rate of rubber lining is 42.5% and rubber lining may meet the anti-seismic requirements of tunnel when crossing fault zone.
机译:近年来的研究表明,穿越断层带时,隧道可能受到严重破坏。因此,断层带衬砌结构的防震设计尤为突出。通过跌落试验,研究了普通混凝土衬砌,钢筋混凝土衬砌和橡胶衬砌在圆形方向上的阻尼水平。试验数据表明,钢筋混凝土的抗震性能优于普通混凝土。橡胶衬砌的地震吸收能力比混凝土衬砌大得多。通过数值模拟,发现衬砌的能量吸收率为42.5%,衬砌穿越断层带时可以满足隧道的抗震要求。