首页> 外文会议>IEEE International Electrical and Energy Conference >Condition Analysis on Implementation of On-Line Monitoring of IGBT Modules of Three-Level NPC Inverters
【24h】

Condition Analysis on Implementation of On-Line Monitoring of IGBT Modules of Three-Level NPC Inverters

机译:三级NPC逆变器IGBT模块在线监测的情况分析

获取原文

摘要

Implementation of on-line monitoring of IGBT modules in the three-level NPC inverters is necessary nowadays. The implementation of on-line monitoring requires an on-line monitoring condition and off-line monitoring technique to attach. In the previous study, it has been researched that the saturated voltage drop (VCE) is one of the most essential diagnostic sign of IGBTs’ healthy status, which is the key point of off-line monitoring technique in the monitoring system. So the on-line monitoring condition is mainly researched in this paper. Analysis has been made to show that it is necessary to force the operating state of monitored phase of inverter to be O state during the on-line monitoring. The results of simulation and experiment of the process of on-line monitoring verify the correctness of the condition analysis in this paper.
机译:如今,需要实施三级NPC逆变器中的IGBT模块的在线监测。在线监控的实施需要在线监控条件和离线监控技术来附加。在以前的研究中,已经研究了饱和电压下降(V. ce )是IGBTS健康状况最重要的诊断迹象之一,是监测系统中离线监测技术的关键点。因此,本文主要研究在线监测条件。已经进行了分析表明,必须在在线监测期间强制逆变器的监控相位的操作状态。在线监测过程的仿真和实验结果验证了本文条件分析的正确性。