首页> 外文会议>International conference on modelling, monitoring and management of air pollution >INDOOR AIR QUALITY MODELLING ON UNIVERSITY BUILDINGS IN TABASCO, MEXICO
【24h】

INDOOR AIR QUALITY MODELLING ON UNIVERSITY BUILDINGS IN TABASCO, MEXICO

机译:墨西哥塔巴斯科的大学建筑室内空气质量建模

获取原文

摘要

Indoor air quality in academic areas has become of vital importance in high educational institutions worldwide. This is very important since students spend a substantial time in such common areas. The current objective of this investigation was to evaluate the air pollutant levels in two common areas (coffee shop and library) at the Juarez Autonomous University of Tabasco, Mexico. The study consisted in monitoring carbon monoxide (CO) and particulate material (PM_(10)) concentration regarding the carbon dioxide (CO_2), temperature (T) and relative humidity (RH). From the indoor air measurements, lineal regression models were also obtained to explain the CO_2, CO and PM_(10) behaviour as a function of the temperature and relative humidity. The hourly average of PM_(10), CO and CO_2 were computed to evaluate the air quality and indoor comfort level based on EPA, WHO and ASHRAE (the American Society of Heating, Refrigerating and Air-Conditioning Engineers) regulations. At the coffee shop, the CO concentration levels were found to be exceeded according to the air quality standards established by WHO. For both library and coffee shop, the mean hourly values of CO_2 and temperature exceeded the maximum values recommended by ASHRAE as comfort levels. Concerning the relative humidity in the library, values of 60 % were recorded exceeding the maximum levels established by ASHRAE. Finally, the current results revealed that temperature and relative humidity played an important role for bacteria growth, indicating its presence for indoor ambient spaces, under similar ambient conditions.
机译:在世界范围内,学术领域的室内空气质量已变得至关重要。这一点非常重要,因为学生会在此类公共区域花费大量时间。这项调查的当前目标是评估墨西哥塔巴斯科州华雷斯自治大学两个公共区域(咖啡店和图书馆)中的空气污染物水平。该研究包括监测有关二氧化碳(CO_2),温度(T)和相对湿度(RH)的一氧化碳(CO)和颗粒物质(PM_(10))的浓度。从室内空气测量中,还获得了线性回归模型来解释CO_2,CO和PM_(10)行为与温度和相对湿度的关系。根据EPA,WHO和ASHRAE(美国供热,制冷和空调工程师协会)法规,计算PM_(10),CO和CO_2的每小时平均值,以评估空气质量和室内舒适度。在咖啡店,根据世卫组织制定的空气质量标准,发现一氧化碳浓度水平超标。对于图书馆和咖啡店,每小时的平均CO_2和温度均超过了ASHRAE建议的舒适度最大值。关于库中的相对湿度,记录到的值超过了ASHRAE确定的最大水平的60%。最后,目前的结果表明温度和相对湿度对细菌的生长起着重要作用,表明在类似的环境条件下,其存在于室内环境中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号