The impact of solar irradiance, ambient temperature and clearness index on the outdoor performance of poly-crystalline (poly-Si) PV modules is considered. This paper highlights the effect on the energy output by changing the clearness index for the Building Integrated Photovoltaic System (BIPV) in Malaysia. Simulation was implemented using MATLAB/SIMULINK and results are compared with the actual monitored data. A case study was presented for a 45.36 kWh system using poly-crystalline module and results show that the energy output differs from 7.23% to 8.52% with clearness index of 0.55 and hence clearness index also influenced the energy output besides solar irradiance and temperature.
机译:考虑了太阳辐照度,环境温度和透明指数对多晶硅(Poly-Si)PV模块的户外性能的影响。本文突出了通过改变马来西亚建筑集成光伏系统(BIPV)的透明指数对能量输出的影响。使用MATLAB / SIMULINK实现模拟,并将结果与​​实际监控数据进行比较。使用聚结晶模块的45.36千瓦时系统提出了一种案例研究,结果表明,由于太阳辐照度和温度,晴度指数的透明度指数与晴度指数相差的7.23%至8.52%。