首页> 外文会议>IEEE International Symposium on Power Electronics for Distributed Generation Systems >Protection of Dual-Active-Bridge Converters Against Underdamped Surge Current by Current Limiting Reactor
【24h】

Protection of Dual-Active-Bridge Converters Against Underdamped Surge Current by Current Limiting Reactor

机译:限流电抗器保护双有源桥式转换器免受浪涌电流不足的影响

获取原文

摘要

The dual-active-bridge (DAB) DC-DC converter is one of the key components in the medium-voltage DC (MVDC) power distribution system. However, the behavior of the DAB converter in DC fault conditions and the corresponding protection method still need to be investigated. This paper first analyses the influence of external short circuit faults on the stress of DAB components. Among all the investigated fault types, the pole-to-pole and pole-to-ground faults with underdamped system parameters are the critical situations regarding the underdamped surge current through DABs. Then, the effect of the DC reactors in mitigating the fault impact on DABs is analytically presented. The conclusions are validated with simulation results.
机译:双有源桥(DAB)DC-DC转换器是中压DC(MVDC)配电系统中的关键组件之一。但是,仍需要研究DAB转换器在直流故障条件下的行为以及相应的保护方法。本文首先分析了外部短路故障对DAB组件应力的影响。在所有调查的故障类型中,系统参数不足的极对极和极对地故障是流经DAB的浪涌电流不足的关键情况。然后,分析了直流电抗器在减轻故障对DAB的影响方面的作用。仿真结果验证了结论。