As the lack of on-spot testing equipment for synchronous Phasor Measurement Unit (PMU), the on-spot testing work of PMU has not been carried out effectively. So the function of Wide area measurement system (W AMS)based on PMU was restricted greatly. In the on-spot PMU testing, the major issues are the implement of the power angle measurement and sufficient dynamic-precision. To solve these problems, we developed a high-precision PMU testing device based on the synchronous clock source in this paper. The proposed device can output amplitude, phase, frequency and low frequency vibrator of signals, which also synchronize with the second pulse of Global Positioning System (GPS). We further constructed the synchronous simulated system by the PMU testing device we developed, which is used for implementing the test on the spot. It is effective not only for static precision, but also for dynamic precision and functions of PMU.
机译:由于缺乏同步相量测量单元(PMU)的现场测试设备,因此PMU的现场测试工作未能有效开展。因此,基于PMU的广域测量系统(W AMS)的功能受到很大限制。在现场PMU测试中,主要问题是功率角测量的实现和足够的动态精度。为了解决这些问题,本文开发了一种基于同步时钟源的高精度PMU测试设备。所提出的设备可以输出信号的幅度,相位,频率和低频振动器,还可以与全球定位系统(GPS)的第二个脉冲同步。我们通过开发的PMU测试设备进一步构建了同步仿真系统,用于现场执行测试。它不仅对静态精度有效,而且对PMU的动态精度和功能也有效。