In this paper a comparison of leakage current between silicone rubber insulators, different shed epoxy resins and the same epoxy shed resin to obtain comparative values between insulator forms and insulator materials used by testing dry conditions and conditions with Different conductivity values are 10mS/cm, 12mS/cm and 14mS/cm. Based on the observation and analysis of data, obtained information that the flow of information available. It was found that the contact angle of the silicone rubber insulator was 81.44°. The different warehouse epoxy resin contact angles from rice husk ash insulators before being crushed had 99,70° contact angles after pulverized nesar changed to 66,09°. The contact angle of the same epoxy flake resin from rice husk ash before being crushed was 110.570° but after tidying the value changed to 70.87°. Based on data observation and analysis, information is obtained that the information flow is available. For conditions that exist on the same insulator at a voltage of 15 kV with a leakage current value of 0.021029 mA and for the smallest leakage is the Silicone Rubber isolator on the 11 kV signal with a leakage current value of 0.013188 mA. For wet conditioning testing conditions with a conductivity value of 10 mS the biggest leakage current is the same sheed insulator with a leakage current value of 0.028755 mA and the least leakage current on the silicone rubber insulator at a voltage of 11 kV with a leakage current value of 0.018699 mA. For wet conditioning testing conditions with a conductivity value of 12 mS the biggest leakage current is the same insulator with sheed with a leakage current value of 0.028929 mA and the least leakage current on the silicone rubber isolator at a voltage of 11 kV with a leakage current value of 0.019837 mA. For testing conditions of wet conditioning with a conductivity value of 14 mS mS the largest leakage current is the same sheed isolator with a leakage current value of 0.029725 mA and the least leakage current on the silicone rubber isolator at a voltage of 11 kV with a leakage current value of 0.020501 mA.
机译:本文比较了硅橡胶绝缘子,不同脱落的环氧树脂和相同的环氧脱落树脂之间的泄漏电流,以通过测试干燥条件和具有不同电导率值的条件分别为10mS / cm,12mS来获得绝缘体形式和绝缘体材料之间的比较值。 / cm和14mS / cm。基于对数据的观察和分析,可获得信息流即可用的信息流。发现硅橡胶绝缘子的接触角为81.44°。碾碎的雀巢粉化为66.09°后,碾碎前的稻壳灰绝缘子与仓库环氧树脂的不同接触角为99,70°。相同的鳞片状树脂与稻壳灰的粉碎前的接触角为110.570°,整理后的接触角变为70.87°。基于数据观察和分析,获得信息流可用的信息。对于在同一绝缘体上存在的条件,电压为15 kV,泄漏电流值为0.021029 mA,对于最小泄漏,在11 kV信号上使用硅橡胶隔离器,泄漏电流值为0.013188 mA。对于电导值为10 mS的湿法调节条件,最大泄漏电流是相同的绝缘子,泄漏电流值为0.028755 mA,硅橡胶绝缘子上的最小泄漏电流为11 kV,泄漏电流值为0.018699 mA对于电导值为12 mS的湿式调节测试条件,最大泄漏电流是同一绝缘体,其泄漏电流值为0.028929 mA,在电压为11 kV的硅橡胶隔离器上泄漏电流最小,且泄漏电流为11 kV值0.019837 mA。对于电导值为14 mS mS的湿法调节的测试条件,最大泄漏电流是相同的绝缘隔离器,泄漏电流值为0.029725 mA,硅橡胶隔离器上的最小泄漏电流在电压为11 kV时有泄漏电流值为0.020501 mA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号