Icing disaster about transmission line has affected the safety of power network. At present, weighing method is an important method and technology for on-line icing-monitoring system, which uses the force transducer to monitor the change of pulling force about the insulator string in order to reflect the wire icing status. However, calculation formula of ice thickness used by many companies not only neglects the important parameters of the line icing characteristics, but also gets nothing about some other useful parameter, so the results of the calculation have great errors, and the engineering application is poor. This paper analyzes some error facts about icing-monitoring device, and provides some advices for formula correction and data analysis.
机译:关于传输线的结冰灾难影响了电力网络的安全性。目前,称重方法是在线冰监测系统的重要方法和技术,它使用力换能器监测绝缘体串的拉动力的变化,以反映电线锦标状态。但是,许多公司使用的冰厚的计算公式不仅忽略了线路结冰特性的重要参数,而且还没有任何其他有用的参数,所以计算结果有很大的错误,而工程应用很差。本文分析了关于糖化监控设备的一些错误事实,并为公式校正和数据分析提供了一些建议。