With the rising demand for electrical energy in an aircraft and the increase in operating voltages of the electrical distribution networks, the probability of occurrence of an arc fault is also increased. New protection devices such as arc fault detectors are now integrated in the network to break the circuit in case of an arcing event. To determine the optimum location of these protection devices, a simplified electrical distribution network is modelled. This network distributes power to common aircraft loads. An electric arc model for circuits as presented in a previous work is then placed at various locations in the network. Simulations of normal arcing and arcing faults are given for each load. Finally, the modification of the spectral content of the network currents is studied to deduce the optimum locations of arc fault protection in the network.
机译:随着飞机中对电能的需求的增加以及配电网络的工作电压的增加,电弧故障发生的可能性也增加了。现在,网络中集成了新的保护设备,例如电弧故障检测器,可以在发生电弧事件时断开电路。为了确定这些保护装置的最佳位置,对简化的配电网络进行了建模。该网络将功率分配给常见的飞机负载。然后将先前工作中介绍的电路电弧模型放置在网络中的各个位置。针对每个负载给出了正常电弧放电和电弧放电故障的仿真。最后,研究了对网络电流频谱内容的修改,以得出网络中电弧故障保护的最佳位置。