摘要

The emergency action level (EAL) scheme for a modular high temperature gas-cooled reactor (HTR) plant refers to the generic EAL development guidance for pressurized water reactors (PWR) with HTR modification due to its design issues. Based on reactor's accidents analysis and consequence assessment, EAL scheme of HTR is established through the steps of category and classification. Four emergency classes are set for HTR consisting of U (Emergency Standby), A (Facilities Emergency), S (Site Area Emergency) and G (General Emergency). The Recognition Category of Initiating Condition (IC) and EAL contains A - Abnormal Rad Levels / Radiological Effluent, F - Fission Product Barrier, H - Hazards and Other Conditions Affecting Plant Safety, S - System Malfunction. The methodology for development of EALs for HTR on Fission Product Barrier and System Malfunction has some differences from PWR's due to differences on operating mode, inherent safety features and system characteristics.
机译:模块化高温气冷堆(HTR)工厂的紧急行动级别(EAL)方案是指由于其设计问题而对经过HTR修改的压水堆(PWR)的通用EAL开发指南。在反应堆事故分析和后果评估的基础上,通过分类和分类的步骤,建立了高温气冷堆的EAL方案。为HTR设置了四个紧急级别,包括U(紧急备用),A(设施紧急),S(站点区域紧急)和G(一般紧急)。初始状态(IC)和EAL的识别类别包含A-辐射水平/放射性排放异常,F-裂变产物屏障,H-危害和影响工厂安全的其他条件,S-系统故障。由于裂变产物屏障和系统故障,HTR的EAL的开发方法与PWR有所不同,这归因于工作模式,固有安全特性和系统特性的差异。