首页> 外文会议>International conference on nuclear engineering >AN EXTENDED APPLICATION RESEARCH OF RELAP5 TO TYPICAL NON-LOCA OF PASSIVE NPP
【24h】

AN EXTENDED APPLICATION RESEARCH OF RELAP5 TO TYPICAL NON-LOCA OF PASSIVE NPP

机译:RELAP5在被动NPP典型非本地化中的扩展应用研究

获取原文
获取外文期刊封面目录资料

摘要

As to passive nuclear power plant (NPP) transient/accident analysis, conservative codes rather than best estimated code such as RELAP5 are mainly used to do the non-LOCA analysis work. While considering the severer accident consequence, RELAP5 is selected in some cases as a tool for LOCA analysis so that safety margin can be gained and meanwhile, the safety NPP condition is guaranteed. In order to extend the RELAP5 application rang to passive NPP, a simulation capability research of RELAP5 to typical non-LOCA consisting of condition II, III and IV transient analysis of CAP1000 was conducted, and the results were compared with that analyzed by safety analysis code. Meanwhile, as to simulation skill, an innovative RELAP5 model was developed. In despite of different conservative degree of the key parameters, the response of the key equipment together with the variation tendency of the key parameters were consistent with that predicted by safety analysis code. Besides, the results met the acceptance criteria. It was showed that RELAP5 has the capability to simulate the CAP1000 non-LOCA.
机译:对于无源核电站的瞬态/事故分析,保守代码而不是诸如RELAP5之类的最佳估计代码主要用于进行非LOCA分析工作。在考虑更严重的事故后果的同时,在某些情况下选择RELAP5作为LOCA分析的工具,这样可以获得安全裕度,同时可以保证安全的NPP条件。为了将RELAP5的应用范围扩展到无源NPP,对CAP1000的条件II,III和IV进行瞬态分析,对RELAP5对典型的非LOCA进行了仿真能力研究,并将结果与​​安全分析代码进行了比较。 。同时,关于仿真技巧,开发了创新的RELAP5模型。尽管关键参数的保守程度不同,但关键设备的响应以及关键参数的变化趋势与安全分析代码所预测的一致。此外,结果符合验收标准。结果表明,RELAP5具有模拟CAP1000非LOCA的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号