A comparative analysis of the methods for obtaining the biological sensor impedance in electrochemical impedance spectroscopy (EIS) systems is made. It is shown that the use of the amplitude-phase method can improve the metrological characteristics of EIS systems due to a significant reduction in power consumption and simplification of the analog interface of the biological sensor. The realization of the peak detector on TSMC 0.35um SiGe technical process is considered. Due to the correction based on the proposed model of the peak detector, a relative error of 0.4% in the 10 GHz band and 3% in the 20 GHz band is achieved.
机译:对电化学阻抗谱(EIS)系统中获得生物传感器阻抗的方法进行了比较分析。结果表明,由于显着降低了功耗并简化了生物传感器的模拟接口,因此使用振幅相位方法可以改善EIS系统的计量特性。考虑了在台积电0.35um SiGe工艺流程上实现峰值检波器。由于基于建议的峰值检测器模型进行了校正,因此在10 GHz频段中的相对误差为0.4%,在20 GHz频段中的相对误差为3%。