This paper deals with an open-circuit IGBTs faults diagnostic method that is dedicated for three-phase two-level voltage inverter fed vector controlled induction motor drive systems. The presented technique is based on a transient analysis of a reference voltage space vector in a stationary reference frame and it does not require an extra sensors application. The diagnostic algorithm ensures to detect and localize single power switch failures in a time shorter than one period of a stator current fundamental harmonic, without regard to a drive operation point. The presented sheme of the diagnostic system can be easy applicable in the electric drives that used voltage space vector modulation (SVM) algorithms. The main achievement of the research, whose results have been presented in this paper, is experimental validation of the IGBTs faults diagnosis technique in the drive with the Direct Torque Control (DTC) algorithm.
机译:本文涉及开放式IGBTS故障诊断方法,专用于三相双级电压逆变器供给载体控制感应电动机驱动系统。该技术基于静止参考帧中的参考电压空间向量的瞬态分析,并且它不需要额外的传感器应用。诊断算法确保在短于定子电流基础谐波的一段时间内检测和定位单电源开关故障,而不考虑驱动操作点。诊断系统的款式可以很容易地适用于使用电压空间矢量调制(SVM)算法的电动驱动器。本文提出的研究的主要成就是具有直接扭矩控制(DTC)算法的驱动器中IGBTS故障诊断技术的实验验证。