Power transformers are crucial components of electric power systems for continuity of electricity. The reliability of power system depends greatly on the operational performance of the power transformers under different operating conditions. The most important indicator of the operating performance of oil-immersed transformers is the top-oil and the hottest-spot temperature values. Therefore, different thermal models have been developed in the literature to estimate temperature changes of power transformers. In this study, thermal models developed by IEC Loading guide for oil and winding temperatures of power transformers are studied. To the best of our knowledge, description of IEC models in the literature have some ambiguous points. Thus, ambiguous points have been clarified and some modification to IEC models has been introduced to have better estimates of top-oil and hottest-spot temperatures of power transformers. With these modifications, top-oil and hottest-spot temperatures, which are given for 250MVA ONAF transformer unit in IEC Annex-b, are presented during different load variations as an example.
机译:电力变压器是电力系统中电力连续性的关键组成部分。电力系统的可靠性在很大程度上取决于电力变压器在不同工况下的运行性能。油浸式变压器的运行性能最重要的指标是顶油和最热点温度值。因此,文献中已经开发了不同的热模型来估计电力变压器的温度变化。在这项研究中,研究了由IEC加载指南针对电力变压器的油温和绕组温度开发的热模型。据我们所知,文献中对IEC模型的描述存在一些歧义。因此,澄清了歧义点,并引入了对IEC模型的一些修改,以更好地估计电力变压器的顶油温度和最热点温度。通过这些修改,以IEC附录b中250MVA ONAF变压器单元给出的最高油温和最热点温度为例,介绍了在不同负载变化期间的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号