This research experimentally measured the characteristic parameters of 10 Gb/s bidirectional optical amplifier: (1) operating wavelength range, (2) small signal gain, (3) Polarization Dependent Loss (PDL), and (4) power consumption. Bidirectional amplifiers are the key component to extend coverage area as well as increase a number of users in Passive Optical Networks (PON). According to 10-Gigabit-capable PON or XG-PON standard, the downstream and upstream wavelengths are 1577 nm and 1270 nm respectively. Thus, our bidirectional amplifier consists of an Erbium Doped Fiber Amplifier (EDFA) and a Semiconductor Optical Amplifier (SOA) for downstream and upstream wavelength transmissions respectively. The operating wavelengths of EDFA and SOA are measured to be from 1570 nm to 1588 nm and 1263 nm to 1280 nm respectively. To measure gain, the input wavelengths of EDFA and SOA were fixed at 1577 nm and 1271 nm respectively, while their input powers were reduced by a variable optical attenuator. The small signal gain of EDFA is 22.5 dB at 0.15 Ampere pump current, whereas the small signal gain of SOA is 7.06 dB at 0.325 Ampere pump current. To measure PDL, which is a difference in output powers at various State of Polarization (SoP) of input signal, a polarization controller was inserted before amplifier to alter input SoP. The measured PDL of EDFA is insignificant with less than 0.1 dB. In contrast, the measured PDL of SOA is as large as 33 dB, indicating its strong polarization dependence. The total power consumptions were measured to be 1.5675 Watt.
机译:本研究通过实验测量了10 GB / s双向光放大器的特征参数:(1)工作波长范围,(2)小信号增益,(3)偏振相关损耗(PDL),以及(4)功耗。双向放大器是扩展覆盖区域的关键组件以及增加无源光网络中的许多用户(PON)。根据10千兆位的PON或XG-PON标准,下游和上游波长分别为1577nm和1270nm。因此,我们的双向放大器分别由掺铒光纤放大器(EDFA)和用于下游的半导体光学放大器(SOA)组成,分别用于下游和上游波长传输。 EDFA和SOA的操作波长分别测量为1570nm至1588nm和1263nm至1280nm。为了测量增益,EDFA和SOA的输入波长分别在1577nm和1271nm处固定,而它们的输入功率通过可变光学衰减器降低。 EDFA的小信号增益为0.15安培泵电流为22.5dB,而SOA的小信号增益为7.06 dB,在0.325安培泵电流下。为了测量PDL,这是输入信号的各种偏振状态(SOP)的输出功率差异,在放大器之前插入偏振控制器以改变输入SOP。测量的EDFA的PDL具有小于0.1dB的微不足道。相反,测量的SOA的PDL与33dB一样大,表明其强的极化依赖性。测量总功耗为1.5675瓦特。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号