Three solutions of an ionic liquid ferrofluid (ILFF) using 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMI.VI-NTG) as the carrier liquid were emitted from a capillary electrospray source and the resulting beam was measured using a time-of-flight mass spectrometer (TOF-MS). The solutions had 3.04, 5.98, and 8.80 wt% iron oxide nanoparticles making them susceptible to magnetic fields. A Helmholtz coil was used to impose a gradient-free magnetic stress onto the electrospray source. Mass spectra were collected in the spray from each of the solutions, with and without the imposed magnetic field. The magnetic stress caused an increase in the peak intensity of distinct ion species (n = 0 or n = 1) at lower energy defects suggesting that the stress causes ions to be born at higher energy. The ratio of the ion peak intensity with magnetic field to ion peak intensity at zero magnetic field was proportional to the concentration of nanoparticles. The magnetic stress did not significantly affect the large mass distributions until the nanoparticle concentration reached 8.80 w t% in the fluid.
机译:从毛细管电喷雾源中发射出使用1-乙基-3-甲基咪唑双(三氟甲基磺酰基)酰亚胺(EMI.VI-NTG)作为载液的离子液体铁磁流体(ILFF)的三种溶液,并用一定的时间测量所得束飞行质谱仪(TOF-MS)。该溶液具有3.04、5.98和8.80 wt%的氧化铁纳米颗粒,使其易于受到磁场的影响。使用亥姆霍兹线圈将无梯度的磁性应力施加到电喷雾源上。在有和没有施加磁场的情况下,从每种溶液的喷雾中收集质谱。磁应力在能量较低的缺陷处导致不同离子物种(n = 0或n = 1)的峰值强度增加,这表明应力导致离子在较高的能量下产生。磁场下的离子峰强度与零磁场下的离子峰强度之比与纳米粒子的浓度成正比。直到流体中的纳米粒子浓度达到8.80 w t%为止,磁应力才不会显着影响较大的质量分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号