In this paper, an analytical method for the thermal analysis of naturally cooled high voltage cable sealing end provided with heat pipe as method of cooling is introduced. In this analytical method, the axial heat flow as well as the heat convection and radiation are taken into account. To validate the analytical method, a comparison between the experimental results that done by others, the finite element method results and the results obtained by this analytical method is done. It is noticed that there is a good agreement between the results of the three methods. Finally, the analytical method is used to investigate the effect of ambient temperature and the thermal resistivity of the insulation on the temperature distribution along the sealing end and the adjacent cable parts.
机译:本文介绍了作为冷却方法的热管的天然冷却高压电缆密封端热分析的分析方法。在这种分析方法中,考虑了轴向热流以及热对流和辐射。为了验证分析方法,完成了由他人完成的实验结果之间的比较,完成了有限元方法结果和通过该分析方法获得的结果。注意到三种方法的结果之间存在良好的一致性。最后,使用分析方法来研究环境温度和绝缘的热电阻率对沿密封端和相邻电缆部件的温度分布的影响。