There has been an increased recognition that more attention needs to be paid to the condition monitoring of hydro-generators to provide a more reliable and sustainable power production. The static eccentricity (SE) fault is one of the prevalent types of failure in the wound rotor synchronous generator that leads to the outage of the power unit. Many different solutions have been proposed for SE fault detection. The techniques are normally based on an offline approach which is not an industry favorite. In this paper, a novel statistical approach is applied to the air gap magnetic field that can detect the fault in its early stage. Furthermore, the severity of the failure on the proposed index in different loading conditions is studied. A polar diagram of the air gap magnetic field is used to detect the location of SE. Finally, the ability of the statistical indices to detect the SE fault in under load variation are verified by experimental results.
机译:已经提高了认识,更有注意力需要支付给水力发电机的状态监测,以提供更可靠和可持续的电力生产。静电偏心(SE)故障是缠绕转子同步发电机中的普遍类型的失效之一,导致电源单元的停机。已经提出了许多不同的解决方案进行了故障检测。这些技术通常基于一个不是行业最喜欢的离线方法。本文施加了一种新颖的统计方法,施加到气隙磁场,其可以在早期检测故障。此外,研究了不同负载条件下提出的指数上的失败的严重程度。气隙磁场的极性图用于检测SE的位置。最后,通过实验结果验证了统计指数检测载荷变异下的SE故障的能力。