Optical-Fiber Pyrometer Positioning Accuracy Analysis

机译:光纤高温计定位精度分析

获取原文

摘要

The influence of the distance between the fiber end and the machined surface on temperature measurements in a two-color fiber-optic pyrometer is analyzed. The propose fiber-optic pyrometer is capable of measuring highly localized temperatures, while avoiding the use of lenses or fiber bundles, by using a standard graded index glass fiber OM1 with 62.5/125 core and cladding diameters. The fiber is placed very close to the target and below the tool insert. The output optical power at both wavelength bands is theoretically and experimentally analyzed for a temperature of 650°C at different fiber positions in a range of 2mm. The results show that there is no influence of the fiber position on the measured optical power and therefore, on the measured temperature.
机译:分析了光纤末端与加工表面之间的距离对双色光纤高温计中温度测量的影响。通过使用具有62.5 / 125纤芯和包层直径的标准渐变折射率玻璃纤维OM1,建议的光纤高温计能够测量高度局部的温度,同时避免使用透镜或光纤束。光纤放置在非常靠近目标的位置,并位于工具插入物下方。理论上和实验上,在2mm范围内的不同光纤位置,对于650°C的温度,都分析了两个波长带的输出光功率。结果表明,光纤位置对测量的光功率没有影响,因此对测量的温度没有影响。