首页> 外文会议>IEEE International Symposium on Power Electronics for Distributed Generation Systems >Snubber circuit design considerations for medium-voltage solid-state switches for high-power inverter-based testing applications: A case study
【24h】

Snubber circuit design considerations for medium-voltage solid-state switches for high-power inverter-based testing applications: A case study

机译:基于大功率逆变器的测试应用中压固态开关的缓冲电路设计注意事项:案例研究

获取原文

摘要

This paper investigates a common problem in the snubber circuits of medium-voltage solid-state AC switches in industrial environments where PWM voltage-source converters are prevalent. The switches considered here were designed to evaluate fault ride-through capabilities for megawatt scale wind turbine generators and other generators with grid-connected stators. It is shown in the paper that, if left unchecked, high-frequency harmonics inherent in the output of inverter-based voltage sources can produce failures in the snubber circuits of AC switches. A case study is presented to analyze this issue, and different solutions are analyzed and implemented to tackle the problem. The experimental results validate the proposed solutions.
机译:本文研究了在PWM电压源转换器盛行的工业环境中中压固态AC开关的缓冲电路中的常见问题。此处考虑的开关旨在评估兆瓦级风力发电机和其他具有并网定子的发电机的故障穿越能力。本文表明,如果不加以检查,基于逆变器的电压源输出中固有的高频谐波会在交流开关的缓冲电路中产生故障。提出了一个案例研究来分析此问题,并分析和实施了不同的解决方案来解决该问题。实验结果验证了所提出的解决方案。