首页> 外文会议>IEEE International Power Electronics and Motion Control Conference >In-situ diagnostics and prognostics of wire bonding faults in IGBT modules of three-level neutral-point-clamped inverters
【24h】

In-situ diagnostics and prognostics of wire bonding faults in IGBT modules of three-level neutral-point-clamped inverters

机译:三电平中性点钳位逆变器IGBT模块中引线键合故障的现场诊断和预测

获取原文

摘要

The reliability of power electronic converters is a major concern in industrial applications because of the use of high-power semiconductor devices, which have high-power density and higher failure rates. Potential defects inside an insulated gate bipolar transistor (IGBT) module can be seen as precursors of being about to wear out, and are important for health monitoring of the IGBT module which is used to enhance reliability. Aiming to do reliability assessment about three-level inverters, this paper proposes an appropriate method based on fault-tolerant control circuit, uniquely fine-tuned for inverter (or general converter) evaluation. The proposed prognostic approach uses terminal voltages of IGBT as a precursors to monitor the bond wire health, which can give accurate predictions and allow operators to observe unhealthy IGBT modules inside a power converter, and then take appropriate measures timely to avoid breakdown.
机译:由于使用了具有高功率密度和更高故障率的高功率半导体器件,功率电子转换器的可靠性成为工业应用中的主要关注点。绝缘栅双极晶体管(IGBT)模块内部的潜在缺陷可以看作是即将磨损的先兆,对于用于提高可靠性的IGBT模块的健康状况监视非常重要。为了对三电平逆变器进行可靠性评估,本文提出了一种基于容错控制电路的合适方法,该方法经过微调,可用于逆变器(或通用转换器)评估。所提出的预后方法是使用IGBT的端电压作为前兆来监视键合线的健康状况,这可以给出准确的预测并允许操作员观察功率转换器内部不良的IGBT模块,然后及时采取适当措施以避免故障。