首页> 外文会议>IEEE International Power Electronics and Motion Control Conference >Sneak circuit analysis for a DCM flyback DC-DC converter considering parasitic parameters
【24h】

Sneak circuit analysis for a DCM flyback DC-DC converter considering parasitic parameters

机译:考虑寄生参数的DCM反激式DC-DC转换器的潜电路分析

获取原文

摘要

Sneak circuit phenomena caused by parasitic parameters are found in a DCM flyback converter. The operating principle and the condition of the sneak circuit are derived. It is found that the voltage stress of the switch can be reduced by sneak circuit analysis. Thus the switching loss is reduced. Moreover, the effects of each parasitic parameter on the voltage spike of the switch are analyzed in detail, which advanced the guidelines for safer design. The DS pulse of the switch can be eliminated by selecting optimal circuit parameters. Simulation results verified the theoretical analysis.
机译:在DCM反激式转换器中发现了由寄生参数引起的潜伏电路现象。推导了潜行电路的工作原理和条件。发现可以通过潜行电路分析来降低开关的电压应力。因此,减少了开关损耗。此外,详细分析了每个寄生参数对开关电压尖峰的影响,为更安全的设计提供了指导。可以通过选择最佳电路参数来消除开关的DS脉冲。仿真结果验证了理论分析。