首页> 外文会议>IEEE International Power Electronics and Motion Control Conference >Feedback linearization with integrator of DCDC buck converter taking into account parasitic elements
【24h】

Feedback linearization with integrator of DCDC buck converter taking into account parasitic elements

机译:通过DCDC降压转换器积分器的反馈线性化考虑到寄生元件

获取原文

摘要

This paper presents the feedback linearization based control of DC/DC buck converter, the output voltage controlled. Also, the presence of parasitic elements are not studied in detail in a previous article, therefore the applied state space model are taking into account of those. The high slew rate of the controller cause inrush current during start-up, which have been examined and reduced. The linearized system has been investigated with linear quadratic regulator (LQR) through an example and simulated via Matlab.
机译:本文提出了基于反馈线性化的DC / DC降压转换器控制,输出电压控制。 而且,在先前的物品中没有详细研究寄生元件的存在,因此考虑到施加的状态空间模型。 控制器的高压摆率导致启动期间的浪涌电流,这已被检查和降低。 通过Linear二次调节器(LQR)通过LIMEAR二次调节器(LQR)来研究线性化系统,并通过MATLAB模拟。