The modular cascaded power electronic transformers (PETs) designed for interfacing AC and DC grids are mostly composed of active front end (AFE) and dual active bridges (DABs). Due to the remarkable difference between primary side and secondary side capacitor voltages of DAB at start-up, high input-inrush current will occur if the phase-shift-control (PSC) of DAB is directly employed, which can pose damage to power devices. This paper proposes a novel soft start-up method for DABs in PET with fast pre-charge process. The duty cycle of primary bridge is dynamically adjusted to precisely limit the peak of input-inrush current, and the regulating range is also enlarged.
机译:设计用于接口AC和DC网格的模块化级联电力电子变压器(宠物)主要由主动前端(AFE)和双极有源桥(DAB)组成。由于DAB在启动时的初级侧和次级侧电容器电压之间的显着差异,如果直接采用DAB的相移控制(PSC),则会发生高输入浪涌电流,这可能会对电力设备造成损坏。本文提出了一种具有快速预充电过程的PET中的一种新型软启动方法。电动桥的占空比是动态调整的,以精确地限制输入浪涌电流的峰值,并且调节范围也扩大。