首页> 外文会议>Conference on Thermal Power Plants >Rotary diode failure detection in brushless exciter system of power plant synchronous generator
【24h】

Rotary diode failure detection in brushless exciter system of power plant synchronous generator

机译:电厂同步发电机无刷励磁系统中旋转二极管故障检测

获取原文

摘要

Reliability and availability of synchronous generator in power plant is related to performance of exciter system that is coupled mechanically and electrically to synchronous generator. This paper focused on the condition monitoring of rotating rectifier diodes in brushless exciter. Two common types of diode failures such as diode open-circuit and diode short-circuit on the one branch of rotating rectifier are simulated during no load and full load conditions. All accessible signals of main generator and exciter are analyzed by FFT method. In the end best signals for detection fault condition are introduced and suitable criteria to distinguish between diode failures are presented.
机译:电厂同步发电机的可靠性和可用性与励磁系统的性能有关,励磁系统机电耦合到同步发电机。本文重点研究无刷励磁机中旋转整流二极管的状态监测。在空载和满载条件下,模拟了两种常见的二极管故障类型,例如旋转整流器的一个分支上的二极管开路和二极管短路。通过FFT方法分析主发电机和励磁机的所有可访问信号。最后,介绍了用于检测故障状况的最佳信号,并提出了区分二极管故障的合适标准。