首页> 外文会议>International conference on microelectronics, electromagnetics and telecommunications >Wavelet-Based Protection Scheme for SVC Compensated Multi-terminal Transmission System with Hybrid Generation
【24h】

Wavelet-Based Protection Scheme for SVC Compensated Multi-terminal Transmission System with Hybrid Generation

机译:具有混合生成的SVC补偿多终端传输系统的小波基保护方案

获取原文

摘要

The majority of transmission system development is easily affected to several temporary and permanent faults due to transients and short circuits. These faults can destroy the transmission network internally and can lead to power system instability. It is necessary to clear these faults within the permissible operating time and have high degree of reliability and security for protective systems. This paper deals about wavelet-based protection scheme for SVC compensated multi-terminal transmission system in presence of hybrid generation. Fault indices are determined by detailed coefficients of current signals at all three terminals using Bior 1.5 mother wavelet. To discriminate the fault on the transmission system, fault indices are compared with a threshold value. The proposed algorithm is found to be reliable, accurate and fast as compared to conventional methods for different types of faults on SVC compensated multi-terminal transmission system with hybrid generation at various terminal locations and fault inception angles.
机译:由于瞬态和短路,大部分传输系统开发容易受到几种临时和永久性故障。这些故障可能会在内部破坏传输网络,可以导致电源系统不稳定。有必要在允许的操作时间内清除这些故障,并具有高度可靠性和保护系统的安全性。本文涉及在混合生成存在下SVC补偿多终端传输系统的基于小波的保护方案。故障指数由使用BiOR 1.5母小波的所有三个端子的电流信号的详细系数确定。为了区分传输系统的故障,将故障指数与阈值进行比较。与不同类型的故障的传统方法相比,该算法被发现是可靠的,准确和快速的用于不同类型的故障在各种终端位置处的混合生成和故障初始角度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号