The authors describe an accelerated technology for circulating fluidized bed combustion. The approach used included a reliability analysis, early system start-up tests, and systematic exploitation of operating experience with similar units that started up earlier. Exploiting experience with earlier units turned out to be the most important of the three actions. Many potential problems were eliminated and the plant passed its reliability acceptance test on the first attempt.
机译:作者描述了一种用于循环流化床燃烧的加速技术。使用的方法包括可靠性分析,早期系统启动测试,并系统地利用早期启动的类似单位的操作体验。利用早期单位的经验证明是这三项行动中最重要的。消除了许多潜在问题,并且该工厂在第一次尝试时通过了其可靠性验收测试。