Fast and accurate coherency identification is necessary for the equivalence transform when real-time analyzing the transient stability of power system. In this paper, a novel method of coherency identification based on Wide Area Measurement (WAMS) is presented. By analyzing the dynamic process of the system, a comprehensive variable is obtained by giving angle, angular velocity and angular acceleration time-varying weights to better reflect the difference of real-time dynamic behavior among generators. Thus, the coherency identification method based on comprehensive variable is put forward. Besides, an evaluation method based on Davies-Bouldin's Index (DBI) is presented to real-time assess the rationality of clustering result. The speed and accuracy of the proposed scheme is verified by simulations on IEEE standard 39-bus 10-unit system.
机译:在实时分析电力系统暂态稳定时,等效变换需要快速,准确的相干性识别。本文提出了一种基于广域测量(WAMS)的相干识别新方法。通过分析系统的动态过程,可以通过赋予角度,角速度和角加速度时变权重来获得一个综合变量,以更好地反映发电机之间实时动态行为的差异。因此,提出了一种基于综合变量的一致性识别方法。提出了一种基于Davies-Bouldin指数(DBI)的评估方法,用于实时评估聚类结果的合理性。通过在IEEE标准39总线10单元系统上的仿真,验证了所提方案的速度和准确性。