Electromagnetic Interference (EMI) is a problem that presents difficulties in placing lines using the most popular methods to locate an on-board circuit failure via an off-line addition interface test for a high-speed maglev train. To find a more practical and more reliable method, probe points have been used to locate the circuit failure by using test probes to obtain the status of the operating circuits. The performance is demonstrated according to theory analysis and a simulation test. The proposed method can avoid additional EMI and is still useful for circuits or systems without considering testing when designing.
机译:电磁干扰(EMI)是一个问题,在使用最流行的方法通过高速磁悬浮列车的离线附加接口测试来定位车载电路故障时,难以放置线路。为了找到一种更实用,更可靠的方法,已经使用探针来通过使用测试探针获得工作电路的状态来定位电路故障。通过理论分析和仿真测试证明了该性能。所提出的方法可以避免额外的EMI,并且对于电路或系统仍然有用,而无需在设计时考虑进行测试。