The drift rate is change of voltage by time dependence, that is isothermal and fixed composition in the solution. In this study, we prepared arrayed flexible chlorine ion sensors which are fabricated by radio frequency sputtering technology and screen-printed technology to measure the drift in the different NaCl solutions, we obtained output voltage in variation concentrations from 10M to 1 M NaCl solutions over 12 hours, the drift rates of the chloride ion sensing devices are 1.122 mV/hr in 1 M NaCl solution, 1.192 mV/hr in 10 M NaCl solution, 2.869 mV/hr in 10 M NaCl solution, 1.529 mV/hr in 10M NaCl solution, 0.988 mV/hr in 10 M NaCl solution and 3.991 mV/hr in 10 M NaCl solution, respectively.
机译:漂移速率是电压随时间的变化,即等温且溶液中的成分固定。在这项研究中,我们制备了阵列式柔性氯离子传感器,该传感器是通过射频溅射技术和丝网印刷技术制造的,用于测量不同NaCl溶液中的漂移,我们获得了在12种浓度范围内从10M到1 M NaCl溶液的浓度变化的输出电压。小时,氯离子感测设备的漂移速率是:在1 M NaCl溶液中为1.122 mV / hr,在10 M NaCl溶液中为1.192 mV / hr,在10 M NaCl溶液中为2.869 mV / hr,在10M NaCl溶液中为1.529 mV / hr分别在10 M NaCl溶液中为0.988 mV / hr和在10 M NaCl溶液中为3.991 mV / hr。