High-powered pulsed powers supply for shipboard launching device in parallel, every unit can discharge hundreds of thousands of amperes current to the launching device, to satisfy the demand of launching, power units discharge in designed sequence. In order to generate hundreds of thousands of amperes current, power voltage must reach ten thousand volt. So the negative pole of power must be grounded to keep the system safe. Analysis results show that current through grounding connection will be generated when multiple points grounding is adopt, this paper calculates out the current through grounding connection by simulation, at last, this paper put forward that single point grounding is suitable for the pulse forming net system, which can eliminate the current through the grounding connection.
机译:船用下水装置的大功率脉冲电源并行供电,每个单元可向下水装置释放数十万安培的电流,以满足下水的需求,动力装置按设计顺序放电。为了产生数十万安培的电流,电源电压必须达到一万伏。因此,电源负极必须接地,以确保系统安全。分析结果表明,采用多点接地时会产生流经接地的电流,本文通过仿真计算得出流经接地的电流,最后提出单点接地适用于脉冲成形网系统;这样可以消除通过接地连接的电流。