Investigation of DC corona discharge properties using UHF method

机译:使用UHF方法研究直流电晕放电特性

获取原文

摘要

Partial Discharge (PD) measurement is well known as powerful method to identify the condition of high-voltage insulation. This paper investigates the properties of the ultra-high frequency (UHF) electromagnetic (EM) wave emanating from the air discharge (corona) under high voltage DC source. By applying both positive and negative high voltage DC ranging up to 135 kV, a rod antenna and a horn antenna were used as UHF sensors to detect any EM wave emission from PD activity and breakdown in air insulation. The experiment results show that typical PD emission signals under positive DC have higher voltage amplitude and wider burst width pulses than the typical PD emission signals under negative DC. Moreover, it is found that the first-peak of EM wave emission under positive DC has negative polarity while under negative DC has positive polarity. In addition, FFT analysis shows that this typical air discharge has dominant amplitude in frequency bands below 250MHz. Another significant result of this experiment is the inability of the horn antenna to detect the EM emission from air discharge.
机译:局部放电(PD)测量是识别高压绝缘状况的有效方法,众所周知。本文研究了高压直流电源下从空气放电(电晕)发出的超高频(UHF)电磁(EM)波的特性。通过施加高达135 kV的正高压和负高压DC,将棒状天线和号角天线用作UHF传感器,以检测来自PD活动和空气绝缘击穿的任何EM波发射。实验结果表明,典型的正向直流下的PD发射信号比负向直流下的典型PD发射信号具有更高的电压幅度和更宽的脉冲宽度脉冲。此外,发现在正DC下的EM波发射的第一峰值具有负极性,而在负DC下则具有正极性。此外,FFT分析表明,这种典型的空气放电在250MHz以下的频带中具有占主导地位的振幅。该实验的另一个重要结果是喇叭天线无法检测到空气排放中的电磁辐射。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号