This paper proposes a stator turn-to-turn fault detection for inverter-fed electric machines using the voltage difference between two neutral points (NP's). By designing machine Y-connected windings with a secondary neutral point (NP), a voltage difference between two NP's appears once a turn fault occurs. Because this fault signal is induced by the voltage difference between two independent windings, only the turn fault reflected signal is resultant. It leads to an important improvement on the fault detection of standard electric machines since NP voltage difference is immune to the influence of saliency and saturation. In addition, the load and speed affect the signal level and frequency but not the diagnostic accuracy. It is possible to monitor a minor turn fault for the operation at zero and very low speed. A 200-W induction machine with designed two independent Y-connected windings is used for the experimental evaluation.
机译:本文提出了一种逆变器馈电电机的定子匝间故障检测方法,该方法利用两个中性点(NP's)之间的电压差进行检测。通过设计带有次级中性点(NP)的Y型连接的绕组,一旦出现匝间故障,两个NP之间就会出现电压差。由于此故障信号是由两个独立绕组之间的电压差引起的,因此仅会产生匝间故障反射信号。由于NP电压差不受显着性和饱和度的影响,因此对标准电机的故障检测有重要的改进。此外,负载和速度会影响信号电平和频率,但不会影响诊断准确性。可以监控零转和非常低的速度下的小转弯故障。实验设计使用一台200 W感应电机,该电机设计了两个独立的Y形连接绕组。