A study of the present knowledge about the bucket resistance for axial loading was performed considering analytical and numerical design methods as well as physical models. A case study was performed with two bucket foundations of equal diameter, but different skirt lengths installed in dense sand. It was found that bearing capacity from the surcharge increases approximately twice if the foundation skirt is two times longer. However, the predicted compressive soil capacity can differ by 3.6 times depending on the chosen bearing capacity parameters. Few methods are available for the estimation of the static tensile resistance for a bucket foundation. Furthermore, the predicted tensile resistance can differ up to 12 times indicating that further analysis is needed approaching this issue.