This paper describes an automatic classification algorithm for nocturnal hypoxemia in patients receiving home oxygen therapy (HOT). Nocturnal hypoxemia is a well-known complication in patients with chronic respiratory disease, and the number of patients receiving HOT has increased in recent years. Many studies have reported that 40% of patients receiving HOT have sleep-related oxygen desaturation. To deal with this situation, a nocturnal pulse oximetry is used to measure oxygen saturation (SpO2) and control the flow rate of highly concentrated oxygen. However, in some cases, the flow rate is not controlled properly and the same flow rate is adopted both during the day and night. There are several types of nocturnal hypoxemia, and it is difficult to classify these types only according to a subjective assessment of a medical doctor. Furthermore, it is difficult to continuously monitor the measurement results of pulse oximetry, although a flexible treatment depending on the state of hypoxemia is desired. To overcome these difficulties, an automatic classification method for SpO2 measured by the nocturnal pulse oximetry is proposed in this paper. The proposed method uses the time domain waveform and the frequency characteristics of SpO2. The classification performance of the method is evaluated by using 48 measured SpO2 values from patients receiving the HOT. The classification results are validated with decisions of ten chest physicians.
机译:本文介绍了接受家用氧疗法(热)患者夜行缺氧血症的自动分类算法。夜间缺氧血症是慢性呼吸道疾病患者的着名并发症,近年来接受热的患者的数量增加。许多研究报告称,40%的接受热的患者有睡眠相关的氧气去饱和度。为了处理这种情况,使用夜间脉搏血氧测定法测量氧气饱和度(Spo 2 )控制高度浓缩氧的流速。然而,在某些情况下,在白天和夜间期间,不正确地控制流速并采用相同的流速。有几种类型的夜间缺氧血症,并且难以根据医生的主观评估来分类这些类型。此外,难以连续监测脉搏血氧测定法的测量结果,尽管需要根据低氧血症状态的柔性处理。为了克服这些困难,SPO的自动分类方法 2 本文提出了通过夜间脉冲血氧测量测量。该方法使用时域波形和SPO的频率特性 2 。通过使用48测量的SPO来评估方法的分类性能 2 来自患者的患者的价值。分类结果验证了十个胸部医生的决定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号