In 2012 an increased number of arcing faults in PV module junction boxes occurred at products manufactured by the company "Scheuten Solar Holding BV". Beside damages to modules and yield losses, also consequential fire damages to buildings happened. The Netherlands consumer product safety authority issued a European safety alert notification (RAPEX) and claimed extended tests for repair solutions as the affected products were certified and tested according to actual standards, but still failed in practice. Additional testing procedures beyond actual standards were defined after intensive discussions in an experts group. Suncycle developed a repair method in cooperation with the Fraunhofer institute for reliability and microintegration (IZM). Extended climatic chamber tests were carried out on original junction boxes as well as on different repair solutions. Measurements and analytical methods could prove the existence of fretting corrosion at original plug connections. The experience with this failure mechanism caused discussions in standardisation committees and adaptations of applicable product certification standards can be expected.
机译:2012年,“ Scheuten Solar Holding BV”公司生产的产品中,光伏组件接线盒中发生的电弧故障数量增加。除了损坏模块和降低产量外,还对建筑物造成了相应的火灾。荷兰消费者产品安全机构发布了欧洲安全警报通知(RAPEX),并声称对维修解决方案进行了扩展测试,因为受影响的产品已根据实际标准进行了认证和测试,但实践中仍未通过。在专家组的深入讨论之后,定义了超出实际标准的其他测试程序。 Suncycle与Fraunhofer研究所合作开发了一种修复方法,以实现可靠性和微集成度(IZM)。在原始接线盒以及不同的维修解决方案上进行了扩展的气候箱测试。测量和分析方法可以证明原始插头连接处存在微动腐蚀。这种失败机制的经验引起了标准化委员会的讨论,并且可以适应适用的产品认证标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号