Conversion of a 2-terminal-pair bridge to a 4-terminal-pair bridge for increased range and precision in impedance measurements

机译:将2端子对桥转换为4端子对桥,用于增加阻抗测量的范围和精度

获取原文

摘要

A new 4-terminal-pair bridge, capable of a relative uncertainty of 1 in 10/sup 9/, has been constructed at NIST by converting a 2-terminal pair bridge. The conversion requires only addition of components which are easily removed if 2-pair measurements are to be made. The design and testing of this bridge are described.
机译:一种新的4端对桥,能够通过转换2端子对桥在NIS中构建了10 / SOP 9 /的相对不确定度。如果要进行2对测量,则转换只需要添加容易移除的组件。描述了该桥的设计和测试。