首页> 外文会议>Annual IEEE Applied Power Electronics Conference and Exposition >Optimum Harmonics Injection to Minimize Bus Capacitance of CRM Boost PFC Conveters Meeting EN61000-3-2 Class D Limits
【24h】

Optimum Harmonics Injection to Minimize Bus Capacitance of CRM Boost PFC Conveters Meeting EN61000-3-2 Class D Limits

机译:最佳的谐波注射,以最大限度地减少CRM Boost PFC FARMERS的总线电容符合EN61000-3-2 D类限制

获取原文

摘要

Based on the energy-ripple perspective, this paper discusses the optimum 3rd and 5th order harmonic injection to minimize bus capacitance of CRM boost PFC converters. Within EN61000-3-2 Class D limits, 34% 3rd and 19% 5th order harmonics injection can theoretically achieve the maximum bus capacitance reduction of 36.1% for wide input application (100~240Vac). However, the conventional on-time control ignores the deviation effect of CRM operation, which introduces the exceeding 3rd and 5th order injected harmonics than EN61000-3-2 Class D limits. In order to eliminate the deviation effect, a novel on-time compensation method is proposed to realize accurate harmonics injection. The experimental results from an 120W prototype show that the maximum bus capacitance reduction of 33% is achieved in practice meeting EN61000-3-2 Class D limits within 100~240Vac input range.
机译:基于能量纹波透视图,本文讨论了最佳的3RD和第5级谐波注射,以最大限度地减少CRM升压PFC转换器的总线电容。在EN61000-3-2中,D类限值,34%3RD和19%的第5次谐波注射可以理论上可以实现宽输入应用(100〜240VAC)的36.1%的最大总线电容减少。然而,传统的接通时间控制忽略了CRM操作的偏差效应,这引入了比EN61000-3-2 D类限制的超过3和5阶谐波。为了消除偏差效果,提出了一种新的逆时补偿方法来实现准确的谐波注射。由120W原型的实验结果表明,在100〜240VAC输入范围内,在练习会议中实现了33%的最大总线电容减少。