The main focus of this paper is to investigate the effect of post-fault reconfiguration on the inverter voltage total harmonic distortion in multilevel inverters (MLI). Three different operating conditions are compared: 1) Healthy, 2) Faulty, and 3) Reconfigured using different methods that utilize inherent inverter redundancy. Literature mostly addresses balancing line-to-line voltage RMS when reconfiguring the inverter after fault occurrence, and line-to-neutral voltage and harmonic content after reconfiguration is ignored. However, line-to-neutral voltage quality is essential for per-phase analysis of Y-connected three-phase loads, neutral point power conditioning when the neutral exists, unbalanced loading conditions, and harmonic content analysis required by some grid interconnection standards such as AS4777 and IEEE1547. This paper first introduces an accurate analytical model to analyze the harmonic content of the line-to-neutral voltage. Then, two fault conditions are introduced into the model and verified in experiments. Three popular reconfiguration methods to mitigate these faults are then evaluated to analyze and compare harmonic content and RMS values of the achieved line-to-neutral voltages. Simulation and experimental results of healthy, faulty, and reconfigured conditions show that the predicted RMS and total harmonic distortion of the line-to-neutral voltage using the proposed model are accurate. Results also show that the line-to-neutral voltage is severely impacted by existing reconfiguration methods.
机译:本文的主要重点是研究故障后重新配置对多级逆变器(MLI)中变频电压全谐波失真的影响。比较三种不同的操作条件:1)健康,2)故障,3)使用使用固有的变频器冗余的不同方法重新配置。文献主要在重新配置故障发生后的变频器时主要解决平衡线到线电压RMS,并且忽略重新配置后的线到中性电压和谐波含量。然而,线到中性电压质量对于Y连接的三相负荷的每相分析至关重要,当中立存在时,中性点功率调节,一些网格互连标准所需的不平衡负载条件和谐波内容分析AS4777和IEEE1547。本文首先介绍了一种准确的分析模型,以分析线到中性电压的谐波含量。然后,将两个故障条件引入模型中并在实验中验证。然后评估三种流行的重新配置来缓解这些故障的方法,以分析和比较实现的线到中性电压的谐波内容和rms值。健康,故障和重新配置条件的仿真和实验结果表明,使用所提出的模型的预测的RMS和总谐波变形的线 - 中性电压是准确的。结果还表明,通过现有的重新配置方法严重影响线到中性电压。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号