The effect of bearing currents in inverter driven induction motors has been investigated and reported for about ten years. Mitigation techniques have been developed and approved by experiments. In this paper, the special situation of troubleshooting in a given configuration such as existing large plants is discussed. The determination of the actual bearing current phenomenon and the development of the appropriate mitigation technique under given circumstances are shown. A new equivalent circuit diagram for the bearing currents in large drives has been developed and used for evaluation of mitigation techniques. Experiences applying the mitigation techniques to a drive suffering premature damages due to rotor ground bearing current are presented and discussed using experimental results.
机译:轴承电流在逆变器驱动的感应电动机中的效果已被研究并报告大约十年。通过实验开发和批准缓解技术。在本文中,讨论了诸如现有大型工厂的给定配置中故障排除的特殊情况。显示了在特定情况下确定实际轴承电流现象和适当缓解技术的开发。已经开发了一种用于大驱动器中的承载电流的新等效电路图,并用于评估缓解技术。使用实验结果呈现并讨论将缓解技术应用于由于转子接地轴承电流引起的驱动遭受过早损坏的经验。