首页> 外文会议>Annual IEEE Applied Power Electronics Conference and Exposition >Transformer-flux-balancing control in isolated bidirectional DC-DC converters
【24h】

Transformer-flux-balancing control in isolated bidirectional DC-DC converters

机译:隔离式双向DC-DC转换器中的变压器磁通平衡控制

获取原文

摘要

The paper presents novel transformer-flux-balancing control methods for the isolated bidirectional full-bridge (FB) converter with active clamp and the bidirectional dual-active bridge (DAB) converter. Both approaches are based on the sensing and control of the transformer magnetizing current. For the isolated bidirectional FB converter the magnetizing current is obtained by sensing a single current, whereas for the DAB converter, both primary and secondary currents of the transformer need to be sensed to obtain the magnetizing current. Since in the DAB converter the magnetizing-current control can lead to excessive dc values of the winding currents, an additional control loop that eliminates the dc value of the primary and secondary currents is introduced. Performance of the proposed flux-balancing control for the isolated bidirectional FB converter was experimentally evaluated on a 2-kW prototype.
机译:本文介绍了带有有源钳位的隔离双向全桥(FB)转换器和双向双有源桥(DAB)转换器的新型变压器磁通平衡控制方法。两种方法都基于感测和控制变压器的励磁电流。对于隔离双向FB转换器,通过感测单个电流获得励磁电流,而对于DAB转换器,则需要感测变压器的一次和二次电流以获得励磁电流。由于在DAB转换器中,励磁电流控制会导致绕组电流的dc值过大,因此引入了一个附加的控制回路,该回路消除了初级电流和次级电流的dc值。在一个2 kW的原型上,通过实验评估了隔离双向FB转换器的拟议通量平衡控制的性能。