首页> 外文会议>International Conference on Optical Fibre Sensors >Radiation hard fiber optic thermo-hygrometers for relative humidity detection in the CMS experiment at CERN
【24h】

Radiation hard fiber optic thermo-hygrometers for relative humidity detection in the CMS experiment at CERN

机译:CERN CMS实验中用于相对湿度检测的辐射硬光纤温湿度计

获取原文

摘要

This work investigates the performances and the radiation hardness capability of optical thermo-hygrometers based on Fiber Bragg Gratings (FBG) technology for humidity monitoring in the Compact Muon Solenoid experiment (CMS) at CERN, in Geneva. Extensive characterizations in terms of sensitivity, repeatability and accuracy on 80 specially produced polyimide-coated FBG sensors and 80 commercial temperature FBG sensors are presented. Progressive irradiation campaigns with γ- ionizing radiations were also performed. Results showed that the sensors sensitivity is unchanged after each radiation exposure; while the wavelength peak exhibits a radiation-induced shift. The saturation properties of this shift are discussed.
机译:这项工作研究了基于光纤布拉格光栅(FBG)技术的光学温度湿度计的性能和辐射硬度性能,该技术在日内瓦CERN的紧凑型μon电磁阀实验(CMS)中用于湿度监测。介绍了在80种特别生产的聚酰亚胺涂层FBG传感器和80种商用温度FBG传感器的灵敏度,可重复性和准确性方面的广泛表征。还进行了使用γ电离辐射的渐进式辐射运动。结果表明,每次辐射后传感器的灵敏度均保持不变。而波长峰值表现出辐射引起的偏移。讨论了该位移的饱和特性。