首页> 外文会议>IEEE Annual Wireless and Microwave Technology Conference >Experimental setup for investigating blood flow measurement by microwave methods
【24h】

Experimental setup for investigating blood flow measurement by microwave methods

机译:通过微波方法研究血流测量的实验装置

获取原文

摘要

This paper presents a setup and measurement results for the proof-of-concept study of the feasibility of measuring flow from heating and cooling thermal response upon applying microwave heating at 900 MHz. A temperature regulated bath/pump system and microwave heating apparatus are used. With respect to various water flow rates, distinct variations in terms of the temperature rise and fall time responses (measured at a depth of about 8 mm in water) versus the flow rate, and their steady-state levels, upon applying microwave heating, are observed. This method is of particular interest in non-invasive measurement of blood perfusion using microwave heating and radiometry. Further discussions in regard to the setup improvement and perfusion estimation from the thermal response measurements are provided.
机译:本文介绍了用于概念验证研究的设置和测量结果,该概念验证研究了在900 MHz的微波加热条件下测量来自加热和冷却热响应的流量的可行性。使用了恒温浴/泵系统和微波加热设备。对于各种水流量,在施加微波加热时,温度上升和下降时间响应(在水中约8 mm的深度处测量)相对于流量及其稳态水平的明显变化是观测到的。该方法在使用微波加热和放射线法对血液灌注进行无创测量中尤为重要。提供了关于根据热响应测量进行的设置改善和灌注估计的进一步讨论。